Life.lab General Building Finishes Specfications
EXTERNAL FINISHES
INTERIOR FINISHES
- Structure
- Floor and column construction of reinforced concrete.
- External walls of precast concrete panel construction.
- Steel framed roof structure.
- Roof
- Colorbond deck roofing supported on steel purlins and beams.
- Insulated with 50mm thick thermal blanket and double sided fire resistant foil with safety mesh.
- Glazing
- A combination of clear and white tinted glass with powder coated aluminium framing.
- Automatic sliding doors to front entry.
- Facades
- Aluminium framed windows.
- Glass balustrading to feature windows.
- Steel grid projecting balconies.
- Off-shutter finish to concrete panels.
- Pre Painted cladding to framed façade features.
- Feature screens in Corten steel.
- Precast feature elements painted.
- Galvanised steel slat screens to parking with coloured acrylic feature panels.
- Foyer
- Polished terrazzo floors.
- Feature panelling.
- Directory board for all tenants.
- Lockable mail boxes for each tenant.
- Internal Walkways
- Corridor walls to suites in off shutter concrete.
- Glazed balustrading.
- Feature perforated metal panels to each tenancy entrance.
- Floors: combination carpet and ceramic tile.
- Directory boards for tenant identification at each lift lobby.
- Disabled Facilities
- Access for disabled to all floors via lift from front entry and from carpark with ramp access.
- Unisex toilet provision for disabled on Ground and Level 3.
- Lighting
- Guarded florescent fittings to under cover car park.
- Special lighting to foyer and lobby spaces on each floor.
- Requisite emergency lighting throughout.
- External security lighting.
- Air conditioning
- Each suite has its own split air conditioning unit.
- Each suite is individually controlled by thermostat.
- Condenser is located on roof deck.
- Lifts
- Two passenger lifts serve car park and all office floors.
- Both lifts are designed to accommodate a stretcher.
- High quality fit out includes tiled floor, stainless steel and laminate finishes to walls.
- Fire services
- Hose reels and extinguishers to conform to relevant
- Entire building is sprinkler protected except car park.
- Hose reels and extinguishers to conform to relevant
- Security
- The front entry doors and car park gates will be fitted with an electronic security card access system.
- An intercom system will facilitate after hours release to front entry doors from each suite.
- Entry to the car park will be via a proximity card and motion sensor for exit.
- Car Park
- Floor and column construction of reinforced concrete.
- Line marking with tenancy identification.
- 2100mm clear height is available for all vehicle access.
- Car park levels are naturally ventilated.
- Motor Cycles and Bicycles
- Motorcycle parking spaces are available on a shared basis.
- Lockable stands are provided to house bicycles with individual lockers for storage of helmets and riding gear.