Specifications > Overview

Life.lab General Building Finishes Specfications

EXTERNAL FINISHES
  • Structure
    • Floor and column construction of reinforced concrete.
    • External walls of precast concrete panel construction.
    • Steel framed roof structure.
  • Roof
    • Colorbond deck roofing supported on steel purlins and beams.
    • Insulated with 50mm thick thermal blanket and double sided fire resistant foil with safety mesh.
  • Glazing
    • A combination of clear and white tinted glass with powder coated aluminium framing.
    • Automatic sliding doors to front entry.
  • Facades
    • Aluminium framed windows.
    • Glass balustrading to feature windows.
    • Steel grid projecting balconies.
    • Off-shutter finish to concrete panels.
    • Pre Painted cladding to framed façade features.
    • Feature screens in Corten steel.
    • Precast feature elements painted.
    • Galvanised steel slat screens to parking with coloured acrylic feature panels.
 
INTERIOR FINISHES
  • Foyer
    • Polished terrazzo floors.
    • Feature panelling.
    • Directory board for all tenants.
    • Lockable mail boxes for each tenant.
  • Internal Walkways
    • Corridor walls to suites in off shutter concrete.
    • Glazed balustrading.
    • Feature perforated metal panels to each tenancy entrance.
    • Floors: combination carpet and ceramic tile.
    • Directory boards for tenant identification at each lift lobby.
  • Disabled Facilities
    • Access for disabled to all floors via lift from front entry and from carpark with ramp access.
    • Unisex toilet provision for disabled on Ground and Level 3.
  • Lighting
    • Guarded florescent fittings to under cover car park.
    • Special lighting to foyer and lobby spaces on each floor.
    • Requisite emergency lighting throughout.
    • External security lighting.
  • Air conditioning
    • Each suite has its own split air conditioning unit.
    • Each suite is individually controlled by thermostat.
    • Condenser is located on roof deck.
  • Lifts
    • Two passenger lifts serve car park and all office floors.
    • Both lifts are designed to accommodate a stretcher.
    • High quality fit out includes tiled floor, stainless steel and laminate finishes to walls.
  • Fire services
    • Hose reels and extinguishers to conform to relevant
    • Entire building is sprinkler protected except car park.
  • Security
    • The front entry doors and car park gates will be fitted with an electronic security card access system.
    • An intercom system will facilitate after hours release to front entry doors from each suite.
    • Entry to the car park will be via a proximity card and motion sensor for exit.
  • Car Park
    • Floor and column construction of reinforced concrete.
    • Line marking with tenancy identification.
    • 2100mm clear height is available for all vehicle access.
    • Car park levels are naturally ventilated.
  • Motor Cycles and Bicycles
    • Motorcycle parking spaces are available on a shared basis.
    • Lockable stands are provided to house bicycles with individual lockers for storage of helmets and riding gear.